Business rules are added by editing your form or workflow. Click the Rules icon in the form designer toolbar shown below to add new business rules and edit any existing rules in your form.

You may create a new rule by clicking on the icon. Your new rule is given a randomly generated name. You can edit the name as described below.

Each rule has three icons. Each is described below.

  • Click the the Image Modified icon to edit an existing rule. You can edit the name, description and statement (JavaScript code) for the rule.
  • Click the icon to delete a rule. Confirm your choice in the dialog that pops up and the rule will be immediately removed. This is an irreversible process so make sure you do not need the rule before you delete it.

Rules can be temporarily disabled by unchecking the ''enabled''' checkbox visible by opening a rule for edit.

Refer to Rules Examples for many real world samples.

Column
width340px

 On this page:

Table of Contents
maxLevel5

...

  • visible : Set to false to hide a control and true to make the control visible.
  • value : Read or write the value of a control. This is not applicable to sections, tabs and other controls where it does not make sense to set a value.
  • enabled : Set to false to disable (grey out) a control so that a user can not change its value and true to enable it. This is not applicable to sections, tabs and other controls that do not make sense to disable/enable.
  • expanded : Set to false to collapse a group control (sections controls only) and true to expand a group control.
  • selected : Set to true to make a tab the selected tab (tab controls only).
  • valid : The value of this property is true if the control contains a valid value otherwise false.  Validity is based on the control’s type.  For instance a numeric control will be invalid if the user enters a string value that cannot be converted to a number.  This property can be read as well as written.
  • required : Set to true to make a control required and display a yellow background color. (NOTE: only affects palette controls and not controls generated from XSD schema data source). This is also a property of section controls. Setting a section required to false automatically sets all inner controls to not required.
  • options : This property enables dynamic setting select control options (radio, dropdown & checkbox controls only).
  • label : This property sets the label seen on any control including sections.
  • help : This property sets the help text.
  • hint : This property sets the hint seen on hover.
  • status : This property sets the error message display whenever the control's value is invalid. The one exception is the Required Property for Controls in an Accessible form/flow .
  • clicked : This property works with trigger controls.  Its initial state is false.  When a user clicks a trigger its state turns true.
  • printable: Set to false to remove the control from both the printable view and PDF submission document.
  • itemAdded : This property works with repeat controls.  Its initial state is false.  When a user clicks "+" to add a repeat item AND when a repeat item is added via a Document URI as the form loads its state turns true.
  • itemRemoved : This property works with repeat controls.  Its initial state is false.  When a user clicks "-" to delete a repeat item its state turns true.
  • itemIndex : This property works with repeat controls. When an itemAdded or itemRemoved event fires the value of itemIndex is set. For itemRemoved events itemIndex will return -1. For itemAdded events itemIndex will give you the index of the added item

...

  • form.load : This property is true when the form is first loading. It is useful for setting default values via rules that you need to be set before the user starts interacting with the form. This also holds true for flows. This property is true when each step of a workflow is first loading.
  • form.unload : This property is true when users click the form's submit button. It is useful for setting control values just prior to the execution of the form's Doc Actions and Form Actions. This also holds true for flows. This property is true when the user clicks the continue button for each workflow step. Refer to this topic for the details about a change in behavior that has been implemented for Forms only.
  • form.positionUpdated : This property is used for the Geo location feature. You can fire a rule using this special identifier every time the position is updated.
  • Activate : Use this property instead of form.load to prevent invalid flow states when navigating back and forth in a workflow.
  • Deactivate: Use this property instead of form.unload to prevent invalid flow states when navigating back and forth in a workflow.

Examples of identifiers used in  rules are:

...

  • Browser independence. We found it impossible to get these to run reliably in so many versions of so many browsers, especially IE. A bug in your rule (e.g. an infinite loop) will crash the browser and in some cases will require a Windows reboot. On the server, these run in separate threads with lower priority and timeouts so it will not impact the form server.
  • The ability for the rule to do server-side things like http:get () to a database connector, invoke a REST service etc. These often reside behind the firewall and are not accessible to the browser.
  • The rules are not exposed to the browser at all so any sensitive information in the rule (e.g. a password) won’t leave the server. However, we do not recommend putting any sensitive information in a rule.
  • Rules can use information like the currently authenticated subject user id, name, email etc. though technically it would be possible to make this available on the browser if required. However, providing this information in the browser is a potential security hole.
  • Rules can also modify a control – in theory, this can cause large-scale changes to the form’s valid state. Think of an optional XML complex type that has a deeply nested data structure inside it with some required and some optional elements. If any element has a value, all the other required elements become required. It’s much easier and efficient to analyze the form on the server although, technically, this is also possible in the browser. It can be extremely slow for large forms, especially in IE or if someone is running on a slower machine.

These pros of excuting rules server-side mitigate the couple cons:

...

There is a potential for performance bottlenecks. However, this is rare since rules are not compute intensive typically. We think the benefits outweigh the drawbacks here.

Dates and Times

There are several special considerations when writing rules using date, time and date/time controls. You can also find many working samples in the Rules Examples chapter.

...

The validator also supports global directives. Use the global directive to identify additional global objects and functions defined in the execution environment and made available to the rule for which it is not appropriate to include a var statement in the rule code itself. One directive can be used to list all additional globals on a single line. Currently there are no known cases requiring the use of the global directive.  

Rule Editor Functions

The Rule Validator includes an enhanced editor designed to provide an easy experience when developing rules.The rule editor box includes the following features:  

FeaturesDescription
Line NumbersLine numbers in the rule code editor make it easier to correlate reported validation errors with the line of code.
Bracket auto closeType a {, ( or [ and the closing bracket is automatically inserted.
Match BracketPlace the cursor on a bracket and both it and the matching bracket are shown in a matching distinctive color (green).
Syntax Hi-lightingJavaScript syntax hi-lighting with keywords, variables, comments, etc. shown in distinctive colors.
Auto IndentNew lines are auto-indented according to generally accepted code formatting rules.
Code FoldingBracketed code blocks (functions, if-then-else blocks, etc.) are collapsible. Click the arrow immediately to the right of the line numbers to collapse/expand code blocks.
Full screen edit mode

Expand the editor to full screen mode if you need more space to work. Click the "double arrow" expand icon (directly above the editor box) or press F2 when your cursor is inside the Rule box to expand to full screen. The ESC key returns you to small window mode.

Auto Complete/HintingWhen composing a rule, the designer can pick from a list of available controls and their properties directly within the rule editor. The pick list is context sensitive and will behave differently based on where the cursor is located when it is invoked. When on a blank space or immediately following an open bracket/brace, it can be manually invoked using Ctrl-Space to bring up a list of controls. Typing a dot (.) immediately after a  control name or after the index ("[i]") that follows a control name will automatically bring up a context sensitive pick list of properties applicable to that control for selection. You can type the first letter of the item you are looking for and the property starting with that character will be highlighted in the list. Continue typing and the matching options will progressively narrow to the characters typed. Double click your choice using the mouse or press the Enter key to select an item. Any other key dismisses the pick list. . See the example below
HelpThe help icon displays a small help window listing the hot keys described above - (F2, ESC and Ctrl-Space)

...

  • START - signals the start of an execution that may span one or more rules and Doc URIs 
  • END - signals the end of the execution of a batch of one or more rules plus the total execution time in milliseconds
  • ERROR - any errors that were thrown NOT in the context of executing rules
  • START_RULE - signals the start of a rule execution
  • END_RULE - signals the end of a rule execution plus the execution time of this one rule in milliseconds
  • RULE_ERROR - any errors that happened while executing the specific rule
  • RULE_EVAL - A message displaying the rule script
  • RULE_DEP - one for each rule dependency. Examples of dependencies are: form.load, trigger clicked, if conditions that trigger rules, control values changes on the right hand side of assignments, etc..
  • RULE_SCHEDULE - shows the next rule to execute and the remaining rules in the agenda/batch. This event makes it a bit easier to track what the rules engine is doing when debugging.
  • PROPERTY_SET - one for each control property set by the current rule
  • HTTP_START - signals the start of an http call (get, put, ...)
  • HTTP_END - signals the end of the http call + status code and timing
  • HTTP_RESPONSE - a message that dumps the first few lines of the http response
  • HTTP_ERROR - any errors that may have been thrown while performing the http call
  • DOC_READ_START - signals the start of a manually set Doc URI read
  • DOC_READ_END - signals the end of a manually set Doc URI read
  • DOC_READ - signals the success or failure of the Doc URI read
  • LOG - a user defined message that can be generated from a rule using frevvo.log('my INFO message') or frevvo.log('DEBUG', 'my debug message')
  • INFO - this statement informs the designer when the set of property values in a flow during form state initialization are ignored.

...

Security Subject Information from LDAP

LDAP supports both the standard subject attributes and custom attributes. When a user is successfully authenticated by the LDAP security manager, Live Forms automatically retrieves Last Name, First Name and Email Address for this user from the LDAP server. You can retrieve custom attributes in addition to the standard ones from Active Directory and pull the data into your form/flow using  business rules. 

...

Attributes with more than one value are also supported. For example, The carLicense attribute can return multiple licenses. You can write a rule to populate dropdown options with those values. Make sure the carLicense attribute is added to the custom field on the LDAP Configuration screen and of course, there are multiple carLicense attributes, each one containing a different value for the dropdown options, set up for appropriate users on the LDAP server.

...

Note

The manager attribute maps to the built-in data - subject.reports. to. This means you can retrieve this value in a rule or use subject.reports.to for flow navigation if you configure the manager attribute in your LDAP tenant.

Execute a Rule on a Specified Workflow Step.

...

Click the View All button to display all the rules in your form/flow. Then use a browser search (Ctrl+F) to highlight all the places in your rules where a particular search item is mentioned. For example, if you were looking for all the rules that set the required property for a section, search for  'SectionName.required' (replace SectionName with the name of your section ) . This view might be helpful when correcting errors reported by the Rules Editor.

...